歡迎來到泰州福聲電子科技有限公司官方網(wǎng)站,這是一家貼片式無源蜂鳴器、高分貝報警器、喇叭廠家、蜂鳴器廠家!
15722819198
產(chǎn)品中心
當前位置:首頁 > 產(chǎn)品中心
  • FSD-3026-12

壓電蜂鳴器FSD-3026-12

產(chǎn)品名稱 : FSD-3026-12

類型 : 壓電蜂鳴器

驅(qū)動方式 : 有源蜂鳴器

工藝 : 引線蜂鳴器

尺寸范圍 : >30mm

詳細說明:

A. SCOPE 
This specification applies piezo buzzer, FSD-3026-12
 

B. SPECIFICATION

No.

Item

Unit

Specification

Condition

1

Oscillation Frequency

KHz

2.4±0.5


2

Operating Voltage

VDC

9 ~ 15


3

Rated Voltage

VDC

12


4

Current Consumption

mA

MAX. 40

at Rated Voltage

5

Sound Pressure Level

dB

MIN. 85

at 30cm at Rated Voltage

6

Tone Nature


Constant


7

Operating Temperature

-20~ +60


8

Storage Temperature

-30 ~ +70


9

Dimension

mm

Φ30x H26

See appearance drawing

10

Weight (MAX)

gram

12.0


11

Housing Material


ABS( Black )


12

Leading Pin


 Wire Type

See appearance drawing

13

Environmental  
Protection Regulation


 RoHS


 
C. APPEARANCE DRAWING  

未標題-4

Tol : ± 0.5      Unit: mm


D.TESTING METHOD    
Standard Measurement conditions
Temperature:25±2℃  Humidity:45-65%

Acoustic Characteristics:
The oscillation frequency, current consumption and sound pressure are measured by the 
measuring instruments shown below

In the measuring test, buzzer is placed as follows:

 

E. VOLTAGE / CURRENT / SOUND PRESSURE CHARACTERISTICS
  30263026
F. RELIABILITY TEST

NO.

ITEM

TEST CONDITION AND REQUIREMENT

1

High Temperature
Test (Storage)

After being placed in a chamber with 702℃ for 96 hours and then being placed in normal condition for 2 hours.
Allowable variation of SPL after test: 
10dB.

2

Low Temperature
Test (Storage)

After being Placed in a chamber with -302℃ for 96 hours and then being placed in normal condition for 2 hours.
Allowable variation of SPL after test: 
10dB.

3

Humidity Test

After being Placed in a chamber with 90-95% R.H. at 402℃ for 96 hours and then being placed in normal condition for 2 hours.
Allowable variation of SPL after test: 
10dB.

4

Temperature Cycle
Test

The part shall be subjected to 5 cycles. One cycle shall be consist of: 
 

Allowable variation of SPL after test: 10dB.

5

Drop Test

Drop on a hard wood board of 4cm thick, any directions ,6 times, at the height of 75cm .
Allowable variation of SPL after test: 
10dB.

6

Vibration Test

After being applied vibration of amplitude of 1.5mmwith 10 to 55 Hz band of vibration frequency to each of 3 perpendicular directions for 2 hours .
Allowable variation of SPL after test: 
10dB.

7

Solderability
Test

Lead terminals are immersed in rosin for 5 seconds and then immersed in solder bath of +3005℃ for 31 seconds .
90% min. lead terminals shall be wet with solder
(Except the edge of terminals).

8

Terminal Strength
Pulling Test

The force of 9.8N(1.0kg) is applied to each terminal in axial direction for 10 seconds.
No visible damage and cutting off.

TEST CONDITION. 
Standard Test Condition              :      a) Temperature : +5 ~ +35℃  b) Humidity : 45-85%        c) Pressure : 860-1060mbar 
Judgment Test Condition             :      a) Temperature : +25 ± 2℃    b) Humidity : 60-70%        c) Pressure : 860-1060mbar 

 

G. PACKING STANDARD 
Each minimum package unit of products shall be in a carton box and it shall be clearly marked with Part Number, quantity and outgoing inspection number. There shall be no mechanical damage on products during transportation and/or in storage.


[返回]

收起
展開